| Product Advantage |
| 1.Compact in design, dust-proof and lightweight |
| 2.Long life of light source, no maintenance |
| 3.High detection accuracy |
| 4.Built-in diluent, no manual operation |
| 5.User free calibration, reagent tray built-in calibration data |
| 6.Microfluidic disc design to avoid cross infection |
| 7.Low operating noise |
| 8. Capacitive touch IPS display, wider viewing Angle, fast operation response; The interactive interface supports Chinese and English options |
|
9.Support LIS system networking, can also configure the local POCT client software
|
| Technical Features |
| 1.Core technology: transmission colorimetry and dry chemistry |
| 2. Blood sampling mode: venous whole blood, serum, plasma |
| 3.Overall design: suitable for biochemical reagent tray and coagulation reagent tray and biochemical coagulation comprehensive tray, small in shape and dustproof |
| 4. Self-test function: monitor the key parts or status of the instrument |
| 5.Calibration function: built-in reagent calibration information on the platter, automatic identification by NFC in the machine |
| 6.Sample adding method: manual sample adding, built-in diluent |
| 7.Quality control: can provide supporting high and low quality control. |
| 8.Printing function: built-in thermal printer |
| 9.Maintenance function: support program upgrade. |
| 10.Operating interface and operating system: Linux system, support Chinese and English operation interface |
| 11.Data storage: 100,000 sample data. |
| 12.Networking function: support LIS two-way transmission function |
| 13.Direct POCT software: Support POCT software client, can synchronize the test report |
| 14.Input mode: capacitive touch, support Chinese and English touch keyboard input. |
|
15.Supporting reagents: the company developed XXXXXXxx, etc.
|
| Technical Data |
| 1. Test items: biochemistry and coagulation, etc |
| 2.Sample type: whole blood, plasma, serum |
| 3、Detection time: 12 minutes |
| 4、sample volume: 90ul\ Coagulation 60ul |
| 5、Test band: 8 bands |
| 6、Detection accuracy: 0.001ads |
| 7、temperature control accuracy: set temperature ±0.3℃ |
| 8、display: 5 inch capacitive touch IPS display |
| 9、 printer: built-in thermal printing |
| 10、Data interface: 4 USB ports, Bluetooth, Wi-Fi, 4G |
| 11、Power supply: 24V, 60W |
| 12、size (mm):242mmx153mmx220mm (length × width × height) |
| 13、Weight :3.8kg |
| 14、working temperature :10~30℃, relative humidity: ≤70% |
| 15、storage environment: temperature -20℃ ~ 55℃, relative humidity not more than 85% |
|
16. Instrument performance indicators
|
| 10. Reagent performance indicators (14 items of liver, kidney, glucose and lipid) Linear range: TP: 30.0 ~ 100.0 g/L; Propagated: 10.0 ~ 60.0 g/L; ALT: 5.0 ~ 510.0 U/L: AST: 5.0 ~ 510.0 U/L: GGT: 10.0 ~ 450.0 U/L; GLU: 220 ~ 25.00 mmo/L; TBIL:3.4-400 umol/L TG:0.45-5.50mmol/L; T - CH2.00 ~ 10.00 tendency for L: HDL - C0.20 ~ tendency for 2.00 / L Associates: 7 ~ 100 umol / : CR: 30.0 ~ 1000.0 umo/L: Urea: 0.90 ~ 20.00 tendency: UA:150.0-1150.0umol/L: 0.980 for the linear determination of the above items. Precision: 1. Repeatability TP: intra-assay CV≤10%; ALB: intra-assay CV≤10%; ALT: intra-assay CV≤20%; AST: intra-assay CV≤20%; GGT: intra-assay CV≤11%:GLU: intra-assay CV≤10%:TBIL: intra-assay CV≤15%; TG: intra-assay CV≤10%; TCH: intra-assay CV≤10%; HDL-C: intra-assay CV≤20%; TBA: intra-assay CV≤15%; CR: intra-assay CV≤12%; Urea: intra-assay CV≤13% UA: intra-assay CV≤12%. 2. Batch difference The inter-batch relative range of ALTAST and HDL-C was less than 20%, and the relative range of other analytes was less than 15% Accuracy: 1. Relative deviation TP: relative deviation ≤10%:ALB: relative deviation ≤10%; ALT: relative deviation ≤15%; AST: relative deviation ≤15%; GGT: relative shore deviation ≤15%; GLU: relative deviation ≤18%; TBIL: relative deviation ≤15%:TG: relative deviation ≤15%; T-CH: relative deviation ≤10%; HDL-C: relative deviation ≤20%:Urea: relative deviation ≤9%:UA: relative deviation ≤15%TBA: relative deviation ≤15%: CR: relative deviation ≤15%. |
| 11. Normal working conditions |
| Power supply voltage ~100-240V, 50/60Hz |
| Rated power is 60W |
| The ambient temperature ranged from 10 ° C to 30 ° C |
| The relative humidity was 30%-70% |
| The atmospheric pressure ranged from 86.0kPa to 106.0kPa |
| Other requirements to avoid direct sunlight, avoid strong electromagnetic field interference |
3 Advantages of Centrifugal Microfluidic Biochemical Analyzer
Intelligent system simple too perate
·Android system, support wireless network and wired network
·Support to link LIS/HIS system
·Add the sample once and put it into the platter to complete the operation
Whole blood is used for accurate detection
· Heparin lithium anticoagulant tube, take the whole blood sample directly for detection
· Plasma and serum samples were equally supportive
· Automatic centrifugation, plasma detection, traditional biochemical methodology, accurate results
Project diversity to meet the needs
· Microfluidic disc chip, cutting-edge innovative technology, 14 kinds of project package combinations to meet the needs Intelligent monitoring and guarantee, stable and safe operation Lyophilized reagents can be effectively stored for one year
Veterinary Diagnosis